{"id":2512,"date":"2023-06-19T09:22:38","date_gmt":"2023-06-19T09:22:38","guid":{"rendered":"https:\/\/fairconditioning.org\/fc-activity\/?post_type=activity&#038;p=2512"},"modified":"2023-06-19T09:22:38","modified_gmt":"2023-06-19T09:22:38","slug":"psychrometric-pathway-plot-for-cooling-of-air","status":"publish","type":"activity","link":"https:\/\/fairconditioning.org\/fc-activity\/activity\/psychrometric-pathway-plot-for-cooling-of-air\/","title":{"rendered":"Psychrometric Pathway Plot for Cooling of Air"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-2\">\n<div class=\"wp-block-column is-layout-flow\">\n<h5 class=\"wp-block-heading\">Objective<\/h5>\n\n\n\n<p>To plot the psychrometric pathway for cooling air.<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Outcome<\/h5>\n\n\n\n<p>Students will develop a deep understanding of psychrometry and variables in the psychrometric chart<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Requirements<\/h5>\n\n\n\n<p>Psychrometric chart<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Prerequisites<\/h5>\n\n\n\n<ol>\n<li>Conceptual knowledge of psychrometry.<\/li>\n\n\n\n<li>Understanding of psychrometric chart.<\/li>\n<\/ol>\n\n\n\n<p><strong><em>Given Data:<\/em><\/strong><\/p>\n\n\n\n<ol>\n<li>Ambient conditions: 25 \u00b0C, 40% RH<\/li>\n\n\n\n<li>Desired condition: 8 \u00b0C&nbsp;<\/li>\n<\/ol>\n\n\n\n<h5 class=\"wp-block-heading\">Procedure<\/h5>\n\n\n\n<p><strong><em>Step 1: <\/em><\/strong>Plot the ambient condition on the psychrometric chart.<\/p>\n\n\n\n<p><strong><em>Step 2:<\/em><\/strong> On the specific humidity line, proceed horizontally towards the left and reach the saturation point (100% relative humidity line).<\/p>\n\n\n\n<p><strong><em>Step 3:<\/em><\/strong> On the saturation line, proceed downwards, until a DBT of 8\u00b0C is achieved.<\/p>\n\n\n\n<p><strong><em>Image:&nbsp;<\/em><\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/lh6.googleusercontent.com\/KHQz4WPNBzdoqMkh5HH67NkA5rt5f6utjQxwYxTSJWHm4gsYpQCVkwrvjQP673hgKCYnYkJMdyn7GCfI9nL3a2d-T8twwJaV3hGUSBDw5SBXJxN-ZMy649t78gjgW0mWUU2d15tURBs-J_0OkB-lfw\" alt=\"\"\/><\/figure>\n\n\n\n<p><em>Psychrometric Pathway Plot for Cooling Air<\/em><\/p>\n\n\n\n<h5 class=\"wp-block-heading\">References<\/h5>\n\n\n\n<p>None<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Source of Idea<\/h5>\n\n\n\n<p><\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Objective To plot the psychrometric pathway for cooling air. Outcome Students will develop a deep understanding of psychrometry and variables in the psychrometric chart Requirements Psychrometric chart Prerequisites Given Data: Procedure Step 1: Plot the ambient condition on the psychrometric chart. Step 2: On the specific humidity line, proceed horizontally towards the left and reach [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"inline_featured_image":false},"activity_subject":[125],"academic_year":[68],"complexity":[59],"content_tags":[514,494],"activity_type":[361],"activity_duration":[516],"acf":[],"_links":{"self":[{"href":"https:\/\/fairconditioning.org\/fc-activity\/wp-json\/wp\/v2\/activity\/2512"}],"collection":[{"href":"https:\/\/fairconditioning.org\/fc-activity\/wp-json\/wp\/v2\/activity"}],"about":[{"href":"https:\/\/fairconditioning.org\/fc-activity\/wp-json\/wp\/v2\/types\/activity"}],"author":[{"embeddable":true,"href":"https:\/\/fairconditioning.org\/fc-activity\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/fairconditioning.org\/fc-activity\/wp-json\/wp\/v2\/comments?post=2512"}],"version-history":[{"count":1,"href":"https:\/\/fairconditioning.org\/fc-activity\/wp-json\/wp\/v2\/activity\/2512\/revisions"}],"predecessor-version":[{"id":2513,"href":"https:\/\/fairconditioning.org\/fc-activity\/wp-json\/wp\/v2\/activity\/2512\/revisions\/2513"}],"wp:attachment":[{"href":"https:\/\/fairconditioning.org\/fc-activity\/wp-json\/wp\/v2\/media?parent=2512"}],"wp:term":[{"taxonomy":"activity_subject","embeddable":true,"href":"https:\/\/fairconditioning.org\/fc-activity\/wp-json\/wp\/v2\/activity_subject?post=2512"},{"taxonomy":"academic_year","embeddable":true,"href":"https:\/\/fairconditioning.org\/fc-activity\/wp-json\/wp\/v2\/academic_year?post=2512"},{"taxonomy":"complexity","embeddable":true,"href":"https:\/\/fairconditioning.org\/fc-activity\/wp-json\/wp\/v2\/complexity?post=2512"},{"taxonomy":"content_tags","embeddable":true,"href":"https:\/\/fairconditioning.org\/fc-activity\/wp-json\/wp\/v2\/content_tags?post=2512"},{"taxonomy":"activity_type","embeddable":true,"href":"https:\/\/fairconditioning.org\/fc-activity\/wp-json\/wp\/v2\/activity_type?post=2512"},{"taxonomy":"activity_duration","embeddable":true,"href":"https:\/\/fairconditioning.org\/fc-activity\/wp-json\/wp\/v2\/activity_duration?post=2512"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}